Voltage Module (Base P/N 82365AT)
This Hi-O interface module is wired to interface the EDGE EVO device (Hi-O Networked Controller & Reader or Standard Networked
Controller) with electronic door components. The Voltage Module provides 24 VDC to 12 VDC conversion from the Hi-O CANbus to Hi-O
enabled readers.
CONNECTION PARAMETER CONDITIONS VALUE
OPERATING
TEMPERTURE
UL REF
NUMBER
CAN PWR (input)
Voltage - Nominal - 10.8 to +24VDC
32° - 122 °F
(0° - 50 °C)
EVMAxNN
x = K for Black
G for Grey
Current - NSC Not Loaded .4mA
Current - MAX Full Load 1.2A
CAN PWR (output)
Voltage - 10 - 12.25VDC
Current - MAX - .32 - 1.0A
CABLE LENGTHS
Hi-O CAN Bus Total Length 100 ft (30 m) -
22AWG●0.65mm●0.33mm
2
Maximum between drops 30 ft (10 m)
22AWG●0.65mm●0.33mm
2
CAN_L IN
CAN_H IN
CAN V+ IN
GND IN
GND OUT
CAN V+ OUT
CAN_H OUT
CAN_L OUT
Brown
White
Red
Black
White / Black
White / Red
White / Gray
White / Brown
EDGE EVO
®
Voltage Module
Model: EVM
InstallatIon GuIde
82365-901,RevB.2
September 2012
©2009-2012HIDGlobalCorporation.Allrightsreserved.
15370 Barranca Parkway
Irvine,CA92618-2215
USA