9292 Jeronimo Road Irvine, CA 92618-1905 EntryProx™ USER MANUAL 4045-905, Rev C.2 February 7, 2007 © 2007 HID Global Corporation. All rights res
Part No. 4045-905, Rev C.2 EntryProx™ User Guide CAUTION – Replace Battery with Panasonic BR1225 only. Use of another battery may present a risk o
EntryProx™ User Guide Part No. 4045-905, Rev C.2 4.2 BEGINNING ENTRYPROX INSTALLATION To mount the EntryProx unit, referring to Figure 2 and Figure
Part No. 4045-905, Rev C.2 EntryProx™ User Guide Figure 3 Pulling Wires through the Backplate 4.3 CONTROLLER KEYPAD WIRING In a standard installat
EntryProx™ User Guide Part No. 4045-905, Rev C.2 5. Reattach the main circuit board to the controller keypad unit. 6. Attach the controller keypad
Part No. 4045-905, Rev C.2 EntryProx™ User Guide 4.4 CONTROLLER KEYPAD WIRING - SECURE INSTALLATION In a secure installation, the waterproof anten
EntryProx™ User Guide Part No. 4045-905, Rev C.2 9. Make the wiring connections for the Request to Exit switch, the door locking devices, the power
Part No. 4045-905, Rev C.2 EntryProx™ User Guide Figure 6 Removing the Antenna Housing Page 16 of 58 February 7, 2007 © 2007 HID Global Corporat
EntryProx™ User Guide Part No. 4045-905, Rev C.2 4.5 ANTENNA HOUSING - SECURE INSTALLATION Mount and wire the antenna housing no more than 10 feet
Part No. 4045-905, Rev C.2 EntryProx™ User Guide 5. Attach the antenna housing to the backplate by inserting the four securing tabs into the backp
EntryProx™ User Guide Part No. 4045-905, Rev C.2 If you plan to use the filler piece as a Request to Exit switch: 1. Remove the two plastic side tab
Part No. 4045-905, Rev C.2 EntryProx™ User Guide Contents 1 ... 4 INTRODUCTION2 ...
Part No. 4045-905, Rev C.2 EntryProx™ User Guide 4.7 INSTALLATION COMPLIANCE FOR UL 294 The EntryProx Model 4045CGNU0 complies with the UL294 Sta
EntryProx™ User Guide Part No. 4045-905, Rev C.2 3. Remove the backing sheet from the tape on the magnet and stick the magnet to the plastic spacer
Part No. 4045-905, Rev C.2 EntryProx™ User Guide Batt.Magnet Aagnet BMMain Electronics BoardKeypadlectronics BoardE Figure 10 Tamper Switch Installa
EntryProx™ User Guide Part No. 4045-905, Rev C.2 5 WIRING Figure 11 illustrates the location and description of the four pin connectors on the main
Part No. 4045-905, Rev C.2 EntryProx™ User Guide 5.1 MAIN RELAY The main relay for the door-locking device is wired to connector P1 on the EntryPro
EntryProx™ User Guide Part No. 4045-905, Rev C.2 5.4 REQUEST TO EXIT INPUT When the EntryProx Request to Exit (REX) input receives a momentary swit
Part No. 4045-905, Rev C.2 EntryProx™ User Guide The Master Code must be changed from the factory default, before any programming can be done. Writ
EntryProx™ User Guide Part No. 4045-905, Rev C.2 2. You have pressed the wrong key in a command sequence Press * to clear the error condition, then
Part No. 4045-905, Rev C.2 EntryProx™ User Guide 6.4 BEFORE YOU START… Before programming cards, determine: How many cards do I have to enroll?If
EntryProx™ User Guide Part No. 4045-905, Rev C.2 6.7 USER TYPES User Types determine what happens when a user presents their card/PIN to the reader
EntryProx™ User Guide Part No. 4045-905, Rev C.2 ... 15 Figure 5 Removing the P4 Connector...
Part No. 4045-905, Rev C.2 EntryProx™ User Guide No User Location can have the same card and/or access PIN code as another User Location. 6.9 ENTER
EntryProx™ User Guide Part No. 4045-905, Rev C.2 Remember to write an entry in your user list: “User:2 Type:1 PIN:1111 Card:0056 Name: John Doe “ 7.2
Part No. 4045-905, Rev C.2 EntryProx™ User Guide 7.4 PROGRAMMING CARD ONLY USE To program Card ONLY use with Command 50, simply omit the keypad PI
EntryProx™ User Guide Part No. 4045-905, Rev C.2 Cards with multiple facility codes or many numbering gaps must be entered by presentation to the rea
Part No. 4045-905, Rev C.2 EntryProx™ User Guide 2. On the EntryProx keypad Press: 53 # user type # start location # ** <present card> <pr
EntryProx™ User Guide Part No. 4045-905, Rev C.2 8 CHANGING OPERATING PARAMETERS Many users will use the EntryProx with the factory default operati
Part No. 4045-905, Rev C.2 EntryProx™ User Guide • Entering a valid [99 # Master code*] sequence • The expiration of the keypad timer The Invalid
EntryProx™ User Guide Part No. 4045-905, Rev C.2 Note: You must change the master code after performing this command. 1. Place the EntryProx unit in
Part No. 4045-905, Rev C.2 EntryProx™ User Guide 3. To disable this feature Press: 30 # 0 # 0 # **4. Press * to exit program mode 8.6 TURNING KEY
EntryProx™ User Guide Part No. 4045-905, Rev C.2 9 DOWNLOADING DATA TO A PDA The EntryProx unit can download a Transaction Log and a Programmed Us
Part No. 4045-905, Rev C.2 EntryProx™ User Guide 1 INTRODUCTION This User’s Guide provides information and instructions for installing, wiring, and
Part No. 4045-905, Rev C.2 EntryProx™ User Guide • Protocol – Printer • Timeout (Seconds) – 30 4. To download data from the EntryProx Unit to th
EntryProx™ User Guide Part No. 4045-905, Rev C.2 9.2 SELECTING TRANSACTION LOG INFORMATION You can selectively program specific transaction events
Part No. 4045-905, Rev C.2 EntryProx™ User Guide The following transaction events can be set/cleared (saved/not saved) and therefore downloaded/not
EntryProx™ User Guide Part No. 4045-905, Rev C.2 10 DOWNLOADING A TRANSACTION LOG Using the optional Palm PDA with the DCD Program, you can downloa
Part No. 4045-905, Rev C.2 EntryProx™ User Guide 3. Place the Palm IR receiver within 1/2” of the EntryProx IR LED (to the right of the yellow LED)
EntryProx™ User Guide Part No. 4045-905, Rev C.2 The Palm PDA will store reports after they are downloaded. FilesTo view a stored report, touch , s
Part No. 4045-905, Rev C.2 EntryProx™ User Guide 10.4 DOWNLOADING A PROGRAMMED USERS LIST The Programmed Users List can be downloaded to the optio
EntryProx™ User Guide Part No. 4045-905, Rev C.2 5. When the list is complete, press * to exit program mode. Here is a description of the Report
Part No. 4045-905, Rev C.2 EntryProx™ User Guide 11.1 PIN CODE OUTPUT IN WIEGAND MODE The system transmits keypad PINs while operating in Wiegand
EntryProx™ User Guide Part No. 4045-905, Rev C.2 12 PROGRAMMING COMMANDS Read the following table before completing programming of your EntryProx u
EntryProx™ User Guide Part No. 4045-905, Rev C.2 The EntryProx unit is compatible with all HID proximity access cards or key tags encoded with up to
Part No. 4045-905, Rev C.2 EntryProx™ User Guide IF YOU WANT Ref PRESS DETAILS TO 7 Set/clear standard 30 # option # s/c See the following Option
EntryProx™ User Guide Part No. 4045-905, Rev C.2 IF YOU WANT Ref PRESS DETAILS TO 9 Download programmed user list (starting at a certain user) 25 #
Part No. 4045-905, Rev C.2 EntryProx™ User Guide IF YOU WANT Ref PRESS DETAILS TO 14 Set propped door 44 # ttt # 0 # ** ttt = propped door time
EntryProx™ User Guide Part No. 4045-905, Rev C.2 IF YOU WANT Ref PRESS DETAILS TO 20A Program new master code into user location 0 50 # 1 # 0000 #
Part No. 4045-905, Rev C.2 EntryProx™ User Guide IF YOU WANT Ref PRESS DETAILS TO 27 Download Transaction Log via IR port 70 # 0 # 0 # ** Hold op
EntryProx™ User Guide Part No. 4045-905, Rev C.2 13 LED/SOUNDER STATUS INDICATIONS Table 2 LED/Sounder Indications LED OR VISUAL/AUDIBLE DESCRIPTI
Part No. 4045-905, Rev C.2 EntryProx™ User Guide LED OR VISUAL/AUDIBLE DESCRIPTION SOUNDER CONDITION Red blink User lockout is active and strik
EntryProx™ User Guide Part No. 4045-905, Rev C.2 Instructions: Do not write on this page - use it as a photocopy master. Copy the chart at a 200%
© 2007 HID Global Corporation. All rights reserved. www.hidcorp.com An ASSA ABLOY Group company HID Global (California, USA) support: tech@hidcorp
Part No. 4045-905, Rev C.2 EntryProx™ User Guide 2.4 SPECIFICATIONS CATEGORY REQUIREMENTS Environmental Operating Temperature –31F to +150F (-
EntryProx™ User Guide Part No. 4045-905, Rev C.2 2.5 DEFAULT SETTINGS The EntryProx unit is shipped with the following default settings. PARAMETER
Part No. 4045-905, Rev C.2 EntryProx™ User Guide 3 INSTALLATION You can install the EntryProx unit by using a standard installation method or a se
EntryProx™ User Guide Part No. 4045-905, Rev C.2 AKBCDEFGHIJL Figure 1 Factory Supplied Parts 3.2 INSTALLER SUPPLIED PARTS LIST • Appropriate DC po
Comments to this Manuals